Washington State University · Global Health – KenyaRADAR Documentation
INV-110654 · Draft v0.1 · 29 October 2026
Doc 12·Trust & Safety

Responsible AI & Model Assurance

How the AI layer is evaluated, constrained, monitored and retrained so that it stays accurate, explainable and safe.

For: EngineeringM&E / researchGovernance & legalLeadership & funderStatus: Draft v0.1Updated: 29 October 2026

In short

  • RADAR's AI has one intended use: help EOC officers classify and escalate events consistently and quickly under DMT-PHE — never to decide on its own.
  • Every model version passes an assurance loop: test sets, offline evaluation, simulation and parallel run, monitored live use, recalibration.
  • Key measures: AI–expert concordance, false-negative rate, citation accuracy, SUS, zero adverse decision events — with thresholds rising at each gate.
  • Known AI risks (prompt injection via free text, hallucination, automation bias, drift) each have a named control.

Why it matters

In outbreak response, a confident but wrong recommendation can delay containment (false negative) or waste scarce teams (false positive). WHO's guidance on large multi-modal models warns specifically about automation bias — professionals overlooking errors or handing difficult decisions to the model. Research The gates make AI performance a funding condition; this document says how that performance is earned and kept.

How this document connects

Labels used in this document: Proposal stated in the funded proposal, stage-gate paper or deck · Research external evidence (see Sources) · Recommended proposed design choice, to be confirmed · Open decision still needed

1Intended use

In scopeOut of scope
Summarising evidence linked to an MER eventClinical diagnosis or treatment advice for individual patients
Explaining which trigger-card criteria are met or missingSetting the escalation level (the rules engine does this)
Drafting recommended actions with citations to approved guidanceSending anything outside RADAR without human approval
Classifying free-text signals into syndromes and places, for reviewProcessing identifiable data on external AI services
Flagging missing information and timeline risksAnswering general questions unrelated to the event in hand

2Principles in practice

WHO's six principles for AI in health, mapped to RADAR controls. Research

WHO principleHow RADAR applies it
Protect human autonomyHuman confirms, modifies or overrides every recommendation; overriding is easy and expected
Promote well-being, safety and the public interestZero adverse decision events as a gate threshold; false-negative ceiling; kill switch to rules-only mode
Ensure transparency, explainability and intelligibilityCitations to document and page; reasoning summary; published model card and error/override log
Foster responsibility and accountabilityNamed decision-maker on every action; audit log; KNPHI owns the model release decision
Ensure inclusiveness and equityPerformance reported per county and per language (English/Kiswahili); no county left with a weaker model
Promote AI that is responsive and sustainableRetraining on Kenyan operational data; open-weight models KNPHI can run; costs in the recurrent budget

3The assurance loop

1 · Define intended use, hazards, metrics 2 · Test sets SIMEX cases, past events, red-team 3 · Offline eval concordance, citations, FN rate 4 · Simulate tabletop + parallel run 5 · Monitor live overrides, drift, incidents 6 · Recalibrate versioned, re-evaluated Release gate no version ships without passing steps 3 and 4
The assurance loop every model version goes through. A new prompt, model, retrieval index or threshold set is a new version. No version reaches users without passing offline evaluation and simulation; live monitoring feeds the next cycle.

A new version is any change to the model, prompt, retrieval index, knowledge-base documents or rule thresholds. Each version gets a model card and release notes, and can be rolled back.

4How performance is measured

MeasureDefinition Recommended
AI–expert concordanceShare of assessed events where the AI-supported classification and level match the expert-panel reference. Report alongside a chance-corrected statistic (weighted kappa) and by outbreak category and site.
False-negative rateShare of events the panel placed at Level 2–3 that the AI-supported path placed lower. Ceiling agreed at Gate 1 Proposal.
Citation accuracyShare of cited passages that exist and support the claim (sampled and checked by reviewers).
Unsupported-claim rateShare of recommendation statements with no supporting citation.
Override rateShare of recommendations modified or overridden, with reasons — a learning signal, not a failure measure.
Adverse decision eventA decision influenced by the AI that delayed or wrongly downgraded a response, or caused harm. Any one is reviewed as a safety incident.
System Usability ScaleTen-item questionnaire scored 0–100; 68 is average, scores above about 80 are in the top 10%. Research
AI-expert concordance Prelim. Gate 1 Gate 2 Gate 3 0.85 0.88 0.90 0.924 System Usability Scale Prelim. Gate 1 Gate 2 Gate 3 75 78 80 85.2 Documentation completeness Prelim. Gate 1 Gate 2 Gate 3 80% 85% 90% n/a gate threshold (minimum) preliminary result, March 2026 (simulation)
The bar rises at each gate. Gate thresholds from the stage-gate paper, next to the March 2026 preliminary evaluation (11 surveillance professionals, 33 simulated interactions). The preliminary scores already clear the Gate 3 bar — the challenge is holding them under real workload, at every site, on real data.

5Risks and controls

Mapped to the OWASP Top 10 for LLM Applications (2025) where relevant. Research Recommended

RiskExample in RADARControl
Missed escalation (false negative)Agent describes a cluster as low-riskLevel always from rules; validator blocks any draft that disagrees; FN-rate ceiling; panel review of all L2–3 events in parallel runs
Alert fatigue (false positives)Many “alert” cards that are discardedAlert budget per EOC; specificity-first detectors; fusion before alert (doc 06)
Hallucinated or outdated guidance (LLM09)Cites a superseded case definitionApproved-documents-only index; citations required and checked; document register with effective dates
Prompt injection (LLM01)Free text in an EBS signal or media item says “ignore previous instructions…”Treat all source text as data, not instructions; isolate it in prompts; tools read-only; output validation
Sensitive information disclosure (LLM02)Model repeats personal details from a line listNo C1 data in agent context by design; output filters; logs reviewed
Excessive agency (LLM06)Agent triggers a GHEC-AI request on its ownWrite tools require named human approval; least-privilege tool scopes
Improper output handling (LLM05)Malformed JSON breaks the workspaceStrict schema validation; render as text, never execute
Supply chain / poisoning (LLM03–04)Tampered model weights or documentsChecksums on model files; signed images; documents only from approved sources
Automation biasOfficers accept drafts without readingTraining; show rules level and evidence first; periodic “blind” review drills; monitor confirm-without-viewing rates
DriftNew reporting patterns lower accuracyMonthly monitoring of concordance proxies and override reasons; retrain triggers
Unequal performanceLower accuracy for Kiswahili text or one countyDisaggregated reporting; targeted test cases

6Test sets and the expert panel

  • Golden set: the 33 simulated interactions from the March 2026 evaluation, the five national SIMEX scenarios, and documented historical events (e.g. RVF 2018, recent cholera and mpox), each with a panel-agreed reference. Held out from any tuning.
  • Adversarial set: ambiguous presentations, conflicting streams, missing data, injection attempts, Kiswahili and mixed-language text.
  • Expert panel: at least three experienced epidemiologists/EOC leads not involved in building the tool; blinded; disagreements resolved by a pre-set rule (e.g. majority, then discussion).

7Monitoring, incidents and the kill switch

  • Published error and override log — a Gate 2 milestone, with a documented benchmarking and recalibration procedure. Proposal
  • Incident reporting: any suspected adverse decision event is logged, reviewed within 5 working days by KNPHI and UM/CGHE, and reported at the next steering committee.
  • Kill switch: KNPHI can switch the agent off instantly; the workspace continues in rules-only mode with full evidence.
  • Retraining: AI model retraining using national EOC operational data is planned in Phase 2 Proposal — every retrained version re-enters the loop at step 3.

8Open questions

  1. What false-negative ceiling will be agreed at Gate 1? Owner: KNPHI + UM/CGHE + foundation
  2. Formal definition of an “adverse decision event”. Owner: KNPHI + KEMRI
  3. Who sits on the expert panel and how are they compensated and kept independent? Owner: KEMRI + WSU
  4. Who signs off a model release — KNPHI system owner, UM/CGHE lead, or both? Owner: Steering committee

Sources

  • INV-110654 proposal — DMT-PHE agentic AI (citations, reasoning trace, human-in-the-loop); Preliminary work (March 2026 evaluation); Phase 2–3 gated decisions.
  • Stage-gate paper — performance thresholds for Gates 1–3; Gate 2 milestone 6.
  • WHO — Ethics and governance of AI for health (2021) and guidance on large multi-modal models (Jan 2024); summary of the LMM guidance.
  • OWASP — Top 10 for LLM Applications 2025.
  • MeasuringU — 5 ways to interpret a SUS score.